B SERIES- ROUND METAL SHELL PANEL MOUNT, THREADED BODY
C SERIES - ROUND METAL SHELL
1. B(*)F Receptacle
2. B(*)M Receptacle
3. C(*)F Receptacle
4. C(*)M Receptacle
B(*)F Receptacle
Panel-mount female receptacle. Mounts with spanner nut from front of panels up to .4375 inches (11.11 mm) thick. Slot in threaded part of housing permits non-turn mounting. Requires 1.25-inch (31.75 mm) diameter minimum mounting hole. Spanner nut is die-cast zinc with satin nickel finish (Series B*F) or black finish (Series B*FB).
| Part No.1 |
Part No. 2 |
Insert Contacts |
| B3F |
B3FB |
3 |
| ¤B4F |
- |
4 |
| ¤B5F |
- |
5 |
| ¤B6F |
- |
6 |
| ¤B7F |
- |
7 |
B(*)M Receptacle
Panel-mount male receptacle. Mounts with locknut from front of panels up to .250-inch (6.35 mm) thick. Requires .812-inch (20.64 mm) diameter mounting hole. For non-turning mounting, can be keyed to ÒDÓ shaped panel hole, or S3519 mounting adapter can be used. Satin nickel finish (Series B*M) or black finish (Series B*MB).
| Part No.1 |
Part No. 2 |
Insert Contacts |
| B3M |
B3MB |
3 |
| B4M |
- |
4 |
| ¤B5M |
- |
5 |
| ¤B6M |
- |
6 |
| ¤B7M |
- |
7 |
C(*)F Receptacle
Female receptacle for panel or chassis mounting. Flange has three .140 inch (3.57 mm) diameter holes for #5-40 mounting screws (not supplied). Mounts from front of panel or chassis in 0.953 inch (24.21 mm) diameter hole.
| Part No.1 |
Insert Contacts |
| C3F |
3 |
| C4F |
4 |
| C5F |
5 |
| ¤C6F |
6 |
| ¤C7F |
7 |
C(*)M Receptacle
Male receptacle for panel or chassis mounting. Flange has three .140 inch (3.57 mm) diameter holes for #5-40 mounting screws (not supplied). Mounts from front of panel or chassis in .766 inch (19.45 mm) diameter hole.
| Part No.1 |
Insert Contacts |
| C3M |
3 |
| C4M |
4 |
| C5M |
5 |
| ¤C6M |
6 |
| ¤C7M |
7 |
1 Satin nickel finish. (standard)
2 "Black-Velvet" finish. (optional)
3 Gold-plated contacts. (optional)
4.Fas-disconnect detent. (optional)
*Number of insert contacts or pins must be specified to complete part number.
click here to download a schematic
drawing
(you will need to have Adobe Acrobat installed on your system to do this)